XS Training Ltd
XS Training Ltd
  • 44
  • 424 948
XS Training Centre
We are proud to announce the 1st birthday of our New XS Training Centre.
The centre is spacious, modern and has a relaxing area for learners to recharge their batteries.
Train online with XS Training and come to our centre to carryout practical elements!
www.xstraining.com
Переглядів: 80

Відео

Taking Notes
Переглядів 5814 днів тому
I wanted to celebrate one of our XS Training learners this week. She has just completed the C&G 2365 Level 2 qualification and produced the most amazing notes throughout the course. The video shows a snippet of the notes written up from the online course. Train with XS Training and go above and beyond!! www.xstraining.com
"Enjoyable Yet Professional" - Why I Choose XS Training For My C&G 2365 Level 2 & Level 3
Переглядів 6121 день тому
If you are looking to start the journey to becoming fully qualified, listen to Steven's review of his experience after choosing XS Training to gain his City & Guilds 2365 Level 2 and Level 3 qualifications.
Step 3 RFC...... Who Knew?
Переглядів 177Місяць тому
Ring Final Continuity is a test a lot of sparks struggle to understand. This video highlights the information needed for step 3 in relation to testing Twin and CPC cable, with the Line and CPC being different size conductors.
C & G 2365 Level 2 Online Course Testimonial from Simon Goodman
Переглядів 157Місяць тому
This testimonial highlights the reason why you should select XS Training as your training provider. The courses we offer take you to JIB Gold accreditation. Be reassured, we do not run courses that are outside the main stream, to becoming a fully qualified electrician. We offer interest free payments for step by step qualifications. We suggest you complete the 2365 Level 2 first, pay it off, be...
Cable Damage vs IR Test Results
Переглядів 329Місяць тому
How much damage needs to be caused to a PVC cable before Insulation Resistance values start to decrease?
City and Guilds 2365 Level 3 in Electrical Installation - High resistance fault
Переглядів 1,3 тис.Місяць тому
This video is an example of what to expect from the 2365 Level 3 online course with XS training. The course is interactive and there is a 2 week block at the ned in centre to go over areas of concern and to carry out practical and written exams.
City and Guilds 2365 Level 2 in Electrical Installation - Transposition
Переглядів 215Місяць тому
Are you looking to get into the electrical industry? The 2365 Level 2 is the first step on that journey. This is an example video of how the theory is taught with XS Training. You will also attend our amazing training centre to carryout practical elements of the course. www.xstraining.com
Work clever, not just hard
Переглядів 1452 місяці тому
At XS Training we teach the conventional ways of working and also give learners an insight into current technologies and tools! www.xstraining.com
Conduit Threading Challenge
Переглядів 1352 місяці тому
Jamie and Richard take on the conduit threading challenge! How long will it take you to thread 70mm of steel conduit?
CK Electric Screwdriver Verses a Handheld Screwdriver
Переглядів 5902 місяці тому
CK Electric Screwdriver Verses a Handheld Screwdriver
How to Become a Qualified Electrician in the UK
Переглядів 1,6 тис.2 місяці тому
There are 3 main ways in which to get qualified and become a JIB Gold card electrician, depending upon your age, experience and existing qualifications. This video takes you through the options so you can understand which is the best route for you.
XS Training Are Helping More Services Personnel to Get A Trade and Prepare For Civvy Street
Переглядів 1417 місяців тому
XS Training is delighted to have been granted approval from ELCAS (Enhanced Learning Credits Scheme) to provide LEVEL 3 Electrical Training courses to former and serving members of the armed forces. The MOD’s Enhanced Learning Credits Scheme (ELC) promotes lifelong learning amongst members of the Armed Forces. The scheme provides financial support in each of a maximum of three separate financia...
City & Guilds 2365 Level 2 Diploma in Electrical Installations Online Course Introduction and Review
Переглядів 1,4 тис.Рік тому
New learner and entrant into the electrical industry, Janderson (Jan) Baptista Da Silva, talks about his experience of studying XS Training Ltd's City & Guilds 2365 Level 2 Diploma in Electrical Installations Online Course. "Doing the Online City & Guilds 2365 Level 2 Course, I found it very easy going through it with all the videos and everything. The website and platform is very self-explanat...
XS Training Review Some Of The Latest New Tools For Electricians
Переглядів 717Рік тому
At XS Training we're lucky enough to have some really good relationships with lots of other great companies in our industry, nutured over the last 12 years since we were founded in 2011. Here our Senor Manager Jamie Gibbs introduces some of the latest new tools for electricians which we use and recommend to make your work both more efficient and safe. In this video we look at the latest Wago 22...
"XS Training Is A Perfect Fit For The Way I Like To Learn"
Переглядів 366Рік тому
"XS Training Is A Perfect Fit For The Way I Like To Learn"
Safe Isolation
Переглядів 7 тис.Рік тому
Safe Isolation
"Without XS Training I wouldn't be in possession of my JIB/ECS Gold Card right now"
Переглядів 687Рік тому
"Without XS Training I wouldn't be in possession of my JIB/ECS Gold Card right now"
"How XS Training guided me through the way to help me achieve my JIB Gold Card"
Переглядів 970Рік тому
"How XS Training guided me through the way to help me achieve my JIB Gold Card"
XS Training Workshop Area - Steel Conduit
Переглядів 1,5 тис.Рік тому
XS Training Workshop Area - Steel Conduit
Fibre Optic Cable Splice
Переглядів 653Рік тому
Fibre Optic Cable Splice
"I achieved my dream to get my JIB Gold Card with XS Training"
Переглядів 1,2 тис.2 роки тому
"I achieved my dream to get my JIB Gold Card with XS Training"
XS Training Learner of the Year 2021
Переглядів 5452 роки тому
XS Training Learner of the Year 2021
NVQ Level 3 Electrical Training Courses Online - Get Your ECS Gold Card With XS Training
Переглядів 9 тис.3 роки тому
NVQ Level 3 Electrical Training Courses Online - Get Your ECS Gold Card With XS Training
It's Never Too Late to Become a Qualified Electrician with the Help & Guidance of XS Training Ltd
Переглядів 1,5 тис.3 роки тому
It's Never Too Late to Become a Qualified Electrician with the Help & Guidance of XS Training Ltd
Becoming A Qualified Electrician... with the Help & Guidance of XS Training Ltd's Online Courses
Переглядів 9783 роки тому
Becoming A Qualified Electrician... with the Help & Guidance of XS Training Ltd's Online Courses
Electrician explains how XS Training Ltd's Online NVQ Course helped him achieve his JIB Gold Card
Переглядів 2,1 тис.3 роки тому
Electrician explains how XS Training Ltd's Online NVQ Course helped him achieve his JIB Gold Card
RING FINAL CONTINUITY AM2 and/or AM2S Training
Переглядів 40 тис.4 роки тому
RING FINAL CONTINUITY AM2 and/or AM2S Training
SY GLANDING AM2 and/or AM2S Training
Переглядів 49 тис.4 роки тому
SY GLANDING AM2 and/or AM2S Training
AM2S and/or AM2 Training, Preparation, Revision - Sample - 3 Phase Motor And D.O.L. Starter
Переглядів 83 тис.4 роки тому
AM2S and/or AM2 Training, Preparation, Revision - Sample - 3 Phase Motor And D.O.L. Starter

КОМЕНТАРІ

  • @brianhewitt8618
    @brianhewitt8618 13 днів тому

    👍

  • @eastm479
    @eastm479 17 днів тому

    Is it essential to do a level 1 ?

    • @XSTrainingLtd
      @XSTrainingLtd 16 днів тому

      No it's not, you can start at Level 2 🙂

  • @user-pw3hw4nz7r
    @user-pw3hw4nz7r 18 днів тому

    How much do you charge for nvq and how much is the am2 prep cheers

    • @XSTrainingLtd
      @XSTrainingLtd 17 днів тому

      Hi, thanks for your questions about our courses. The NVQ have three different price bands depending upon if you want to add the AM2 and Prep Course from the outset. You can find more about the NVQ 2357 qualification (inc. pricing) here - www.xstraining.com/nvq-2357-electrical-installation-course/ The AM2 Prep Course is available in two options - 14-day Access Only & a Full Year's access. You can find out more about this Course and the different price bands here - www.xstraining.com/online-am2-preparation-course/ Please do get in touch through the Contact details on our website if you have any further questions. Thank you

  • @justchillman104
    @justchillman104 24 дні тому

    Im starting my apprenticeship in september at 16 any big tips/advice ahead of it

    • @XSTrainingLtd
      @XSTrainingLtd 23 дні тому

      Ask as many questions as you can early on. Specifically on site where you will learn so much in such little time. If you don't ask the questions early, you miss vital information which leads to nothing else making sense. No question is a stupid question!!

  • @KaceyJackson-nl2wh
    @KaceyJackson-nl2wh 29 днів тому

    How do you earth to back box as this is what they want on am2 not sure if the rings should be outside or inside the dol stater . Thanks

    • @XSTrainingLtd
      @XSTrainingLtd 23 дні тому

      Hi Kacey, thanks for the message. I have spoken to my colleagues and this can be done either externally and internally on site. However, the some AM2 centres prefer this to be done internally which I know is a bit fiddly. The only reason you would normally do it on the inside is to ensure the gland stays at the relative IP rating. Therefore, try do it internally. You wont fail if done as the video shows. Hope this helps.

  • @MrDannyt1967
    @MrDannyt1967 Місяць тому

    Top info thanks for your time and effort

  • @ethangraham5944
    @ethangraham5944 Місяць тому

    On the fault where 3 and 6 flash up at the same time would that be classified as a short circuit or wrong connection

    • @XSTrainingLtd
      @XSTrainingLtd 23 дні тому

      Hi Ethan, Thanks for your comment. You could class this as a short circuit and this is due to a "wrong connection"

  • @IAmBigDaddy17
    @IAmBigDaddy17 Місяць тому

    Spot on explanation and procedure

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      Thank you for your comment. Please also be aware of any additional supplies, such as solar panels and battery storage.

  • @paul_my_plumbs_uk
    @paul_my_plumbs_uk Місяць тому

    🎉🎉🎉🎉Simon

  • @pauldavies1693
    @pauldavies1693 Місяць тому

    Brilliant! Do you have other video's you explain things better than my college lecturer? 😃❤

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      Thank you for your comments. Yes we do a lot of our courses online with the addition of in-house sessions to bridge any concerns. Foe example, the 2391-52 Inspection and testing. You get 6 months access to the online content, then you come into centre for the 3 days of prep and exams. All the health and Safety etc can be done online prior to coming in. Contact me on 08001700294 if you need more info.

  • @timsky99
    @timsky99 Місяць тому

    most important lesson here for sparks...just strip off the cable and throw it on the ground - there should always be a generous layer of crap left behind when you've completed the job

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      Electricians do get some stick for not being the tidiest on site. We believe, having a tidy working area highlights professionalism and care for your work.

  • @mohamedsiadabdille7631
    @mohamedsiadabdille7631 Місяць тому

    Thanks for excellent explanation how to test High resistance in circuit

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      No worries at all Mohamed. Hope it helps.

  • @dylanmckibbin8822
    @dylanmckibbin8822 Місяць тому

    Hi mate could u do video on testing for am2 tips and tricks, etc writing out test sheets validating results thank you

    • @XSTrainingLtd
      @XSTrainingLtd 20 днів тому

      @dylanmckibbin8822 The full process is included in the full AM2 preparation course. Please sign onto our XS Training Academy and you can purchase the full course. Cheers

  • @wasswambowa8572
    @wasswambowa8572 Місяць тому

    XS please do m video on SWA three phase socket

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      @wasswambowa8572 Can you be more specific? I am more than happy to do this with more info. Is this for the AM2? Is this into an isolator or motor? Thanks.

    • @wasswambowa8572
      @wasswambowa8572 Місяць тому

      Yes is about AM2 SWA cable with gland for three phase socket installation

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      @@wasswambowa8572 The glanding process is included in the full course. Please sign onto our XS Training Academy and you can purchase the full course there. Cheers

  • @matthewcampbell9956
    @matthewcampbell9956 Місяць тому

    You helped me pass my AM2 first go! Many thanks mate!

    • @hixlax5764
      @hixlax5764 Місяць тому

      any advice on the AM2, I am about to start practicing before booking, any tips mate?

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      Really appreciate your message. The AM2 preparation course is great for steadying the nerves and giving you the best chance of showing your skills off to NET. Well done for passing the AM2

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      @@hixlax5764 have a look at our AM2 prep videos on UA-cam. You can buy the full preparation course from our XS Training Academy.

    • @hixlax5764
      @hixlax5764 Місяць тому

      @@XSTrainingLtd will do thank you, I've done my NVQ with you guys and you've been brilliant, you've made it straight forward, the ease of taking pictures and uploading them for the E Portfolio is a big plus, also you're assessors are very knowldgeable as well, I personaly had a good experience with you, it's a shame you're not in London, I would've went with you to do the AM2 and Pre training as well before the exam

  • @jamesphillips5896
    @jamesphillips5896 Місяць тому

    Great instructional technique, clear and informative. Well in, that man.

  • @jmnaeem5885
    @jmnaeem5885 Місяць тому

    hi i'm from bangladesh and i will come in uk september session. Now, i'm learning level 1 so what wil i do? when i will reach in uk. my university campus in london

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      Hi @jmnaeem5885, You can join our City and Guilds 2365 Level 2 in Electrical Installations. The course is online with a 2 week practical course in Leeds, West Yorkshire. Contact me on 0800 170 0294 for more information.

  • @mJyN10
    @mJyN10 2 місяці тому

    Hi I have completed my masters in electrical and electronics engineering, i want to know about the procedures for becoming electrician.ty

    • @XSTrainingLtd
      @XSTrainingLtd Місяць тому

      Hi @mJyN10 How many years have you been working in the trade? Ring me on 08001700294 to discuss further. Regards Jamie

  • @nivregc5544
    @nivregc5544 2 місяці тому

    Ever used a Dewalt DCF680?

    • @XSTrainingLtd
      @XSTrainingLtd 2 місяці тому

      Hi, I can't find the DCF680. I have located a similar product in the Dewalt range. Is this it? - DCF682N1 8V MAX Gyroscopic Inline Screwdriver by DEWALT

  • @jimm533
    @jimm533 2 місяці тому

    Great videos very clear explanations 👍

    • @XSTrainingLtd
      @XSTrainingLtd 2 місяці тому

      Thanks for the positive feedback Jimmy, much appreciated 👍

  • @matthewcampbell9956
    @matthewcampbell9956 3 місяці тому

    How do you know what to do in singles and what to do in flex? Does the spec say?

    • @XSTrainingLtd
      @XSTrainingLtd 3 місяці тому

      Hi Matthew, yes the spec will give you all the information. Cheers

    • @matthewcampbell9956
      @matthewcampbell9956 3 місяці тому

      @@XSTrainingLtd thanks for the reply! Got my AM2 tomorrow. Terrified 😂 but your videos have been a good help

    • @XSTrainingLtd
      @XSTrainingLtd 3 місяці тому

      @@matthewcampbell9956 You're welcome and thanks for the positive feedback about the videos. Best of luck for your AM2 tomorrow! 👍

  • @Notyel
    @Notyel 5 місяців тому

    I got my results back and this is the only bit i have to retake 😢

    • @XSTrainingLtd
      @XSTrainingLtd 5 місяців тому

      All the best for your retake 🤞

  • @Wawaw738
    @Wawaw738 6 місяців тому

    Why are they asking for SY cable to be used to supply a motor ?

    • @XSTrainingLtd
      @XSTrainingLtd 5 місяців тому

      Hi, this is on the specification of the AM2 practical assessment you will have to take.

  • @leventakses1185
    @leventakses1185 6 місяців тому

    Welldon son do you have nvq2 and 3 first

    • @XSTrainingLtd
      @XSTrainingLtd 6 місяців тому

      Hi Levent, Zubar doesn't have access to answer this directly but, from memory, he didn't have these exact qualifications because he came to the UK with lots of practical experience within the industry and qualifications relevant to the countries he worked in which were acceptable to City & Guilds

  • @sparkiegaz3613
    @sparkiegaz3613 7 місяців тому

    Personally found ex forces that go into construction are the most opinionated individuals you can work with or choose not to unfortunately…especially if they go into health and safety 😮

  • @joelbradley1511
    @joelbradley1511 8 місяців тому

    just wondering if the correct cables to use will be specified on the wiring diagram in the am2? just think its a lot to remember off by heart .

    • @XSTrainingLtd
      @XSTrainingLtd 8 місяців тому

      Hi Joel apologies for the delayed response... Yes, there will be a wiring diagram to hand in the AM2 for the learner to follow step by step. Happy New Year and all the best for your AM2 when you come t take it!

  • @monikacieminska5380
    @monikacieminska5380 10 місяців тому

    Hi .Great videos 😃👍just bought Am2 preparation course from you. Could you tell me how many cores does your flex have from the solar controller to main control box please? From the video looks like you are using 3cores (L,N,E). What about connection between R2- in the solar controller and no16 in the main control box? Thank you for your help.much appreciated

    • @XSTrainingLtd
      @XSTrainingLtd 10 місяців тому

      Hi Monika, thanks for purchasing the AM2 Preparation course and thank you too for bringing this to our attention. Yes, a 4 core is required due to a change in spec and we will update the video in the course as soon as we possibly can. Many thanks once again Monika, much appreciated.

  • @shaqeelquraishi2407
    @shaqeelquraishi2407 11 місяців тому

    Thanks love you from Poland ❤

  • @claytonharris5599
    @claytonharris5599 Рік тому

    why do we test at the bottom of the switch as i’ve seen the same video someone else does it at the top

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi Clayton, thanks for your question. It all depends on where you are isolating. In this video the incoming supply to the whole board is isolated. Some videos just isolate the main switch to the board so will test the top of the main switch. Hope that helps.

  • @harrycrosby-oldershaw373
    @harrycrosby-oldershaw373 Рік тому

    Thanks for the help from all ur videos. Passed first time ❤️

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      You're welcome Harry, thanks for taking the time to comment and let us know they help you 👍

  • @brianhewitt8618
    @brianhewitt8618 Рік тому

    👍

  • @Adywebb123
    @Adywebb123 Рік тому

    My angle grinder does most of them jobs, them and my side cutters. Job done.

    • @XSTrainingLtd
      @XSTrainingLtd 2 місяці тому

      Thanks for your comments - Sometimes with the need for hot works permits, its tough to get a grinder on sites. Especially commercial sites.

  • @faisalhussain589
    @faisalhussain589 Рік тому

    My advice would be - connect every cable you pull in and then move on. This will stop you missing anything and getting confused

  • @stephencunningham8850
    @stephencunningham8850 Рік тому

    Thats ok on primary side of DB but what if there was a cross connection from another board on the secondary side iv seen that before at the MCB

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Great point, I shall add this to the video, as we can also get an external supply from PV sources coming in from elsewhere etc. Thank you for your comment.

  • @ryanvesey8645
    @ryanvesey8645 Рік тому

    Hey, how does it tell you if it’s Point A or point B which has the fault? Thank you.

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi Ryan, thanks for your question. This would be a visual check. The basic testing equipment would only tell you what the fault is. If you wanted to check this on site a TDR would be needed. A fluke would tell you if the fault was near or far end. Hope that helps

    • @ryanvesey8645
      @ryanvesey8645 Рік тому

      Thanks , just wanted to verify if it told you which specific outlet the fault was on as the AM2s want it very specific. Thanks for your reply.

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      @@ryanvesey8645 You're welcome 🙂

  • @pauljerome3263
    @pauljerome3263 Рік тому

    wrong, please tell me how you can prove isolation when you have not proved its live in the first place this is a fundamental error all safe isolation procedures have, test its live first

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      This could only be actioned if the installation was live in the first place. The method shown in the video is for all installations which proves dead by showing zero volts on an AVI, and then proceeding to prove the AVI is working on a proving unit. This confirms that when testing dead in the first place, these results were accurate. I will add to the video the need of checking live first where possible. I like you’re thinking and really appreciate your comments, as if you checked dead on something that was already switched off, this could be assumed to be fed from a certain point, but could become energised from another source at a later date within the job.

  • @detroutspinners9933
    @detroutspinners9933 Рік тому

    Great video

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Thanks, much appreciated 🙂

    • @detroutspinners9933
      @detroutspinners9933 Рік тому

      @@XSTrainingLtd likewise. Currently sitting my AM2S and if I get anywhere near passing it’ll be because of you guys and GSH/eFixx.

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      @@detroutspinners9933 You're very welcome and thanks again. All the best with your AM2S when you come to take it

    • @uplightuk8924
      @uplightuk8924 Рік тому

      @@detroutspinners9933 How did you get on?

    • @detroutspinners9933
      @detroutspinners9933 2 місяці тому

      @@uplightuk8924passed! Anyone watching this about to take theirs, if you pay attention to these videos you won’t go far wrong

  • @garyfifield5858
    @garyfifield5858 Рік тому

    I WOULD GRATFULL IF SOME WOULD STATE CABLE RATING IN AMPS AND CSA OFTHIS CABLE BUILDING AM2 RIG CAN ANY PLEASE REPLY DONT TO WAIST MY MONEY THANKS

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Apologies for the late response to this... This is a 1.5mm2 4 core SY

    • @garyfifield5858
      @garyfifield5858 Рік тому

      25 HYARS OF NOT DOIG AM2 IS DRIVING MY CRAZY HOWDO I APPEAL AGIANST NET

    • @XSTrainingLtd
      @XSTrainingLtd 2 місяці тому

      @@garyfifield5858 use the following link to access the appeals document for NET. www.netservices.org.uk/policies-and-procedures/

  • @mikhugh4326
    @mikhugh4326 Рік тому

    good vid , 1 question - i qualified via jib apprentaship in 95 236 part 1-2 am2 , i dropped out of the game , 2023 recently i wanted to get back into the electrician game , i opened a ecs account and put my national insurance number in to the ecs site and they confirmed i was eligible for a gold card !! which i got , problem is i dont have any experience in the modern game and dont want to chance it , so i asked a few sparky people if i could go on site as an improver to slowly get back in the game, i was told that esc will strip me of the gold card if i do that , do you have a any info on this situation ?

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi Mik, many thanks for your kind comments about this video. Regarding your question, it's best to give us a call or send an email so we can speak with you directly about this, as we will need a bit more info from you to give the best response. You can do so on 01535 657059 or email enquiries@xstraining.com. (You can mention that you left a comment here on UA-cam but plerase bear in mind that you will have to run through your situation again anyway as we have a few people that answer the phone and may be not be aware of your question here). Many thanks once again

  • @emilgemc8913
    @emilgemc8913 Рік тому

    SY cable is more For A/C

  • @stewardeastes8240
    @stewardeastes8240 Рік тому

    🤤 Promo`SM

  • @pcjacobsullivan7443
    @pcjacobsullivan7443 Рік тому

    Is there a permanent line link to add in to terminal 4 as well as as terminal 2 within the 2 channel timer ?

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi. Unlike the link of Line to terminal 2 in the timer there is no need to do this for terminal 4. The live feed to 4 comes from elsewhere in the system (the room stat). The drawing in the video shows this but I do appreciate that you'll have to 'pause' it to see it properly.

  • @MrBeaastt1
    @MrBeaastt1 Рік тому

    Hi. I'm about to start my L2 2365 leading to L3 domestic installer. Just not sure about 2357 portfolio as how long does it take and number and type of jobs that I have to undertake in order to gain nvq L3.

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi there, The 2357 portfolio requires you to cover 4 cables and 5 containments. You get 3 years to complete the portfolio. Singles Twin and CPC FP SWA Steel Conduit and Trunking PVC Conduit and Trunking Tray The cables and containments above can be done over as many jobs you require to gain the relevant evidence. Hope that helps but if you need any more details then please feel free to get in touch with us directly through our website, email or phone call. All the best.

  • @springhy
    @springhy Рік тому

    Hello on the channel timer do you have to put a line link from L to 2

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi, it all depends on the centre you do the AM2 at. This link could already be in or you may need to add it yourself. It does however need to be there.

  • @intercity125
    @intercity125 Рік тому

    EN61243-3:2010 and onwards two-pole voltage indicators cannot use fuses for protection as it introduces a risk of false clear indication; proving should alleviate this but the standard went that way anyway.

  • @westlondonrider3094
    @westlondonrider3094 Рік тому

    better instruction than my college i was wrapping them wrong the other way so tightening the nut was pushing strands out.

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Thanks for your positive feedback on our training video, really pleased that it helped you.

  • @DaveWHU91
    @DaveWHU91 Рік тому

    Does anyone know how you would do an insulation resistance test on this? I failed this on my AM2

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi Dave, you need to test IR from the board and then again from the load side to ensure you test the supply and load side. Test between L1 - L2, L1 - L3, L2 - L3, L1 - N, L2 - N, L3 - N, L1 - CPC, L2 - CPC, L3 - CPC and N - CPC from both ends.

    • @maxdunning5612
      @maxdunning5612 Рік тому

      did you test both sides of the DOL ? use the plugs on the simulated motor box to test IR to the DOL, same when you do r1+r2. hope this helps

  • @ibrahimabdullah4430
    @ibrahimabdullah4430 Рік тому

    I'm scared that I wont be able to do it n will lose my money, but I'm gonna try it 👊😎

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi, first of all apologies for not picking up on this and responding sooner. We can appreciate your apprenhension because MANY other people feel exactly the same before they get started. You can see this if you check out our previous reviews on Google and Trustpilot. These will also show you how much easier it is than they first thought when they eventually get started. We always have someone who can call you back and talk you through whats involved but the first step is to complete our Online Application Form to tell us a bit about your previous experience (if any). There is absolutely no obligation to begin one of our courses after completing it but it is the best first step. www.xstraining.com/online-application-form/ Hopefully hear from you soon. 🙂

    • @manshanyuen
      @manshanyuen Рік тому

      I am exactly one of those and am still thinking@@XSTrainingLtd

  • @RhylMotionNew
    @RhylMotionNew Рік тому

    Do you identify your control switched circuits ?

  • @nathancurtis2585
    @nathancurtis2585 Рік тому

    Are all the terminals between the isolator and the top of the contactor already done? And is the sy cable already pre made up of is that something you have to run yourself.

    • @XSTrainingLtd
      @XSTrainingLtd Рік тому

      Hi Nathan, thank you for your comment. The control cables are prewired within the DOL, yes. The only part you will need to do, is the supply to the Isolator using singles and then install and gland off the SY cable. Please watch the video in relation to the control cables though, as you will need to know these connections when you come to the fault finding.